Our product range includes a wide range of fluke 1507 insulation tester, dit918 and digital insulation tester.
₹ 43,220 /Piece Get Latest Price
Color | Yellow |
Usage/Application | Insulation Resistance Testing |
Model Name/Number | fluke 1507 |
Weight | 550 g (1.2 lb) |
Batteries | Four AA batteries (NEDA 15A or IEC LR6) |
Ip Rating | 40 |
Warranty | one-year |
1kV Insulation Tester with PI, DAR - 50V,100,250V,500V, 1000V
Fluke 1507 Insulation Resistance Tester
AC/DC Voltage Measurement | ||
Accuracy | Range | 600.0 V |
Resolution | 0.1 V | |
50 Hz to 400 Hz ± (% of Rdg + Digits) | ±(2% + 3) | |
Input impedance | 3 MΩ (nominal), < 100 pF | |
Common mode rejection ratio (1 kΩ unbalanced): | > 60 dB at DC, 50 or 60 Hz | |
Overload protection | 600 V rms or DC | |
Earth Bond Resistance Measurement | ||
Range/Resolution | 20.00 Ω | 0.01 Ω |
200.0 Ω | 0.1 Ω | |
2000 Ω | 1.0 Ω | |
20.00 kΩ | 0.01 kΩ | |
Accuracy | ±(1.5% + 3) | |
Overload protection | 2 V rms or DC | |
Open circuit test voltage | > 4.0 V, < 8 V | |
Short circuit current | > 200.0 mA | |
Insulation Specifications | ||
Measurement range | 0.01 MΩ to 10 GΩ | |
Test voltage | 50 V, 100 V, 250 V, 500 V, 1000 V | |
Test voltage accuracy | + 20%, - 0% | |
Short circuit current | 1 mA nominal | |
Auto discharge | Discharge time < 0.5 second for C = 1 µF or less | |
Live circuit indicator | Inhibit test if terminal voltage > 30 V prior to initialization of test | |
Maximum capacitive load | Operable with up to 1 µF load | |
Measure accuracy | 50 V | |
100 V | ||
250 V | ||
500 V | ||
1000 V | ||
General Specifications | ||
Maximum voltage applied to any terminal: | 600 V AC rms or DC | |
Storage temperature | -40°C to 60°C (-40°F to 140°F) | |
Operating temperature | -20°C to 55°C (-4°F to 131°F) | |
Temperature coefficient | 0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F) | |
Relative humidity | ||
0% to 95% @ 10°C to 30°C (50°F to 86°F) | ||
0% to 75% @ 30°C to 40°C (86°F to 104°F) | ||
0% to 40% @ 40°C to 55°C (104°F to 131°F) | ||
Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | |
Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) | |
Electromagnetic compatibility | In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) | |
Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) | |
Certifications | CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition | |
Batteries | Four AA batteries (NEDA 15A ) |
₹ 3,600 /Piece Get Latest Price
Color | Red |
Packaging Type | Box |
Display Type | Digital |
Model Name/Number | Metrix+ DIT 918 |
Weight | 550g |
Accuracy | +-5%rdg +- 5dgt |
Batteries | 6 x AA batteries |
Warranty | 1 year |
Brand | Metrix+ |
Minimum order quantity: 1 Piece
Technical SpecificationsModel Metrix+ DIT 918Safety standard IEC 61010-1 CAT III 600VIEC 61010-031(Test wire) Pollution Level 2Test range 100V: 0 ~ 199.9MΩ, 250V: 0 ~ 499.9MΩ, 500V: 0 ~ 999.9MΩ, 1000V: 0 ~ 19.9GΩ, 2500V: 0 ~ 49.9GΩAccuracy ±5%rdg ± 5dgtDC/AC Voltage 30 ~ 600VResolution 1.0VOverload Protection AC 1200V/10secWithstand Voltage AC 8320V/5secInsulated Impedance 1000MΩMax. short circuit current 1.3mAAdditional functionalities Backlight, auto discharge, auto power off, live warning with audio sound, low voltage indicationOperating temperature 0 ~ 50CStorage temperature -20 ~ 70CPower 6 x AA batteriesSize & weight 125.4 x 174.6 x 69 mm, 550gStandard accessories Main unit, test wires, alligator clips, carry case, user manual, batteries
Features Backlit LCD display. Auto discharge. Live wire warning system with audio sound. Auto power off.
₹ 3,800 /1 Get Latest Price
Usage/Application | Insulation Resistance Testing |
Material | PVC |
Packaging Type | Box |
Display Type | Digital |
Color | Black |
Brand | Fluke |
Grade | Semi-Automatic, Automatic |
Power | Cell |
Frequency | 50 % |
Brand: Metrix+
Product Code: DIT918
Reward Points: 0
Availability: In Stock
Product Details
This Digital Megger Equipment or Insulation Tester with LCD Display is a highly sensitive device used to test above ground pipeline insulators. An insulation tester can be used to determine the integrity of windings or cables in motors, transformers, switchgear, and electrical installations. The test method is determined by the type of equipment being tested and the reason for testing.
Installation Testing
The most important reason for using a megger or insulation tester is to insure public and personal safety. By performing a high DC voltage test between de-energized current- carrying (hot), grounded, and grounding conductors, you can eliminate the possibility of having a life-threatening short circuit or short to ground. This test is usually performed after the initial installation of the equipment. This process will protect the system against miswired and defective equipment, and it will insure a high quality installation, customer satisfaction, and protect against fire or shock.
Maintenance Testing
The second most important reason for using a megger or insulation tester is to protect and prolong the life of electrical systems and motors. Over the years, electrical systems are exposed to environmental factors such as dirt, grease, temperature, stress, and vibration. These conditions can lead to insulation failure, resulting in loss of production or even fires. Periodic maintenance tests can provide valuable information about the state of deterioration and will help in predicting possible failure of the system. Correcting problems will result not only in a trouble-free system, but will also extend the operating life for a variety of equipment.
Highlights:
Sanjay Mittal (Proprietor)
Comet Instruments
DM-119 Sukhalia behind namrata tent house
Mob98932-31873, Indore - 452010, Madhya Pradesh, India